DOLPHINGASSYSTEMSPVTLTD 568fb3509ec66806d4d98051 False 67 4
OK

Dolphin Gas Systems Pvt Ltd

About

We undertake Design, Supply, and Installation & Commissioning of LPG systems/ Natural Gas systems on Turnkey basis as per IS Code & Safety Norms. We have completed more than 300 projects all over India in Residential, Commercial and Industrial installation. We have also completed large size Residential Township projects more than 2000 Tenements.

Latest update

LPG Reticulated Systems: The purpose of Dolphin LPG Reticulated system is to provide uninterrupted supply of LPG to the customers through meters. This amounts to a great convenience to the customer.
view all updates 1479449820

Products

LPG/Natural Gas Piping for Residencial , Commercial & Industrial Projects
LPG/Natural Gas Piping for Residencial , Commercial & Industrial Projects INR 0 INR 0 We DGSPL are authorised vendor for Maharashtra Natural gas ltd. for doing natural gas piping/system in western India. We have completed many projects in natural gas system/piping in commercial and industrial installation. True 1453699381
56a5b1359ec6680c5000f975
-0%
LPG Reticulated Systems for Residential Projects
LPG Reticulated Systems for Residential Projects INR 0 INR 0 The purpose of Dolphin LPG Reticulated system is to provide uninterrupted supply of LPG to the customers through meters. This amounts to a great convenience to the customer. All the LPG cylinders are located in the cylinder cage at the Ground level ; effective factor of safety is increased to a great extent. (Cylinder is located outside the home) Also the possible damage to the floor and lift is eliminated. The LPG system has 2 manifolds, out of which, one is the manifold in operation and the other is the stand by manifold. Both the manifolds have respective isolation valves situated at the top end for execution of change over operation. The control system comprises of a filter first stage regulator, Slam Shut off valve, Safety relief valve, second stage regulators, pressure gauges and meters. The filter incoming gas passes through SLAM Shut Off Valve which protects against failure of first stage regulator beyond pressure of 1.2 Kg/ cm². In case of a failure of first stage regulator, Slam Shut Off Valve prevents passage of LPG with direct pressure going to the point of use. The Slam Shut Off Valve cuts off the supply of LPG in case of failure of first stage regulator. Further to the fist stage regulator Additional provision of safety Relief Valve is made as an extra safety. In case of a very rare simultaneous failure of First stage regulator and slam shut off valve The safety relief valve operates and continuously exhausts gas to the atmosphere till such time as all the gas in the cylinders is exhausted, prevents gas to reach user point with direct pressure. A non-return valve provision is made to the pipeline to prevent back flow of LPG. LPG then travels through the risers and reaches the kitchen through isolation valve to the meter through a second stage regulator. The second stage regulator regulates the pressure to the extent of 280 mm of water column. A meter is provided for counting units in terms of meter cube of gas for actual consumption. Main Components of Dolphin LPG Reticulated system The main components of Dolphin LPG Reticulated system are as follows. --Gas Bank A --Isolation valve for Gas Bank A --Gas Bank B --Isolation valve for Gas Bank B. --Pressure gauge No. 1(range 0to 10kg/cm²) --Filter, Slam Shut Off Valve, First Stage Regulator and safety Relief --Valve. --Pressure gauge No.2 (range 0 to 2.2kg/cm²) --Isolation Valve for Each Building Risers --Flame Arrestor --Isolation Valve inside the Kitchen. --Line regulator. --Meter --QT (Quarter Turn) isolation valve near appliances True 1453699544
56a5b1d89ec6680214f23383
-0%
Vapor off Take (VOT) for Commercial & Industrial Projects
Vapor off Take (VOT) for Commercial & Industrial Projects INR 0 INR 0 The ‘N’ no. Of Cylinders are connected to the manifold & the Vaporized LPG is directly drawn from the cylinders with Natural Vaporization Process. This vaporized LPG is passed through the properly designed 1st Stage & 2nd Stage Pressure Reducing Station. This LPG VOT facility is normally recommended for Low utility consumption per hour of LPG. Advantages of VOT Systems: --Requires Less Area --Very convenient to handle 47.5 Kg Cylinders --No residual loss --Constant Pressure --Easy availability --Cheaper then Bulk installations True 1453699429
56a5b1659ec6680c5000f97a
-0%
Liquid off Take (LOT) for Commercial & Industrial Projects
Liquid off Take (LOT) for Commercial & Industrial Projects INR 0 INR 0 LPG Liquid off Take (LOT) System is advanced concept in Multi-cylinder Installation which overcomes problems and demerits of bulk LPG Installation & conventional Manifold (VOT) system. Liquid LPG off Take per cylinder will be (up to 10 Kg/Hr) which is comparatively much more than normal Vapour off Take per cylinder (0.5 -0.6kg/hr) Advantages of LOT Systems: --Requires Less Area --Very convenient to handle 47.5 Kg Cylinders --No residual loss --Constant Pressure --Easy availability --Cheaper then Bulk installations True 1453699483
56a5b19b9ec6680214f2337d
-0%
View All

Our timings

[IS_BIZ_OPEN] Mon: 10:00AM  -  6:30PM
[IS_BIZ_OPEN] Tue: 10:00AM  -  6:30PM
[IS_BIZ_OPEN] Wed: 10:00AM  -  6:30PM
[IS_BIZ_OPEN] Thu: 10:00AM  -  6:30PM
[IS_BIZ_OPEN] Fri: 10:00AM  -  6:30PM
[IS_BIZ_OPEN] Sat: 10:00AM  -  6:30PM
[IS_BIZ_OPEN] Sun: Closed  -  Closed

Contact

Dolphin Gas Systems Pvt Ltd Vittal Mallya Road, Bengaluru
+91 9822090274  or   or   
Please keep or 0 before the
number when you dial.
Share Tweet
False

SUBSCRIBE

More

0 0 Dolphin Gas Systems Pvt Ltd Dolphin Gas Systems Pvt Ltd Vittal Mallya Road, Bengaluru
568fb3509ec66806d4d98051DOLPHINGASSYSTEMSPVTLTD57c3c1a65d69370d7cf4bb19